The device is mainly designed for corporate users, and can be
widely used in chemical, petroleum, metallurgy, coal system, the
on-site guidance for product installation and commissioning, taking
into account the harmonic problem of business users , we can design
reactors rate of 4.5 series reactance or more to make business
users get a certain control of Harmonics. Second, the device can be used for large-scale rural substation,
considering the characteristics of rural substation, load and
seasonal variation of diurnal variation to achieve the maximum
reactive power compensation system. Third, the device can be used for urban network unattended
substation, with "four remotes". Fourth, the device can be used to
transform capacitor devices in the old substation to improve the
level of substation automation and operational level. Main features Special vacuum switch is used which passed the capacitor capacitive
switching back to back test, impact resistance, suitable for
frequent switching. Automatic compensation is divided into 2-5 road switching, high
precision compensation, the impact is small, can maximize the
effect of reactive power compensation. Controller uses intell6 bit microcontroller, a large-screen
character display menu with a friendly interface, real time display
of operating parameters and fault information; with RS-485
communication interface, to achieve four remote functions with the
substation automation interface, to achieve place, three back-plane
and scheduling control and management. 4. Controller with "nine domain areas" control theory, automatic
identification of substation transformers and capacitors of various
operation modes, to prevent switching shock. 5. Each Way capacitor with over-current protection and internal
fault protection, timely and effective fault isolation capacitors,
and with voice alarm capabilities, to protect the overall safety
and reliability. Main technical parameters Installation: Indoor and outdoor products using box changing style Control roads :2-5 road, a choice of more than 5 road in the form
of the two groups. Input quantities: the export of the current bus (5A), voltage
(100V). Control of physical :2-5 Road, vacuum switches, transformer
tap-load transfer capacity. Protection: over current, over voltage, loss of pressure, internal
voltage protection fuse + open triangle. Show: current, voltage, power factor, each capacitor running. Operation Mode: Automatic, Manual Selectable. Rated voltage: 6,10 kV Rated capacity: 600 ~ 5000kvar. Single Maximum capacity: not more than 1000kvar. Series Reactor rate: 0.1%, 4.5%, 6%, 12% optional. Implementation of the standard: JB / T 7111-93 <<High Voltage
Shunt Capacitor Installation>> GB50227-95<<Shunt
Capacitor Installation Design Standards>> |
Model Description: For example: TBBZ10-6005-AK T: Complete installation BB: Parallel compensation Z: automatic compensation 10: System Nominal Voltage 10kV 6005: Nominal capacity 3000kvar, divided into 5-way auto-switching,
the capacity of each road To 600kvar. A: Y connected K: open triangle voltage protect |
See more products from this supplier.
Do you want to show products of your own company? Join FREE now!